6. COOLING SYSTEM                                                         MXU 500 IRS


 Install the water pump cover and tighten the
 bolts to the specified toque.

 Torque: 1.3 kgf-m (13 N-m, 9 lbf-ft)




                                                Water Pump Cover/O-ring


                                                                            Water Hose

 Connect the water hoses and bypass hose,
 then tighten the hose bands.

 Fill the system with recommended coolant
 and bleed the air (refer to the "COOLANT
 REPLACEMENT" section in this
 chapter).




                                                       Water Hose          Bypass Hose




6-13