like 200 i Manuel atelier : Page 178

Microfiches
Image preview

Page 176

Image preview

Page 177

Image preview

Page 179

Image preview

Page 180

1 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190
          16. ELECTRICAL EQUIPMENT                                           LIKE 200i

                                                                  Starter Relay

 STARTER RELAY INSPECTION
 Remove the foot-floor cover.
 Disconnect the starter relay coupler and
 then remove the starter relay.




 Connect the starter relay (D) terminal to the
 12V battery positive (+) terminal and the
 relay (C) terminal to the battery negative (-)
 terminal. Check for continuity between
 the starter relay (A) and (B) terminals.
 The relay is normal if there is continuity.




 STARTER MOTOR REMOVAL
 Disconnect the starter motor cable.
 Remove the two bolts attaching the starter
 motor and remove the starter motor.
 The installation sequence is the reverse of
 removal.




                                                  Starter Motor

13