          20. ELECTRIC STARTER                                                       MYROAD 700i


    (From previous page)



  Check for loose or poorly        Abnormal      ·Poorly connected terminal
  connected starter relay switch
  terminals.

              Normal


  Check for loose or poorly        Abnormal      ·Poorly connected starter motor cable.
  connected or broken starter                    ·Open circuit in starter motor cable.
  motor cable.

              Normal


  With the ignition switch           Clicks       Connect the starter motor terminal
  turned to "ON", push the                        directly to the battery positive
  starter switch and check for a                  terminal (Because a large amount of
  click sound from the starter                    current flows, do not use a thin wire).
  relay switch.
                                                                              Starter motor
              No clicks                        Starter motor turns            does not turn


                                                                     ·Faulty starter motor.

                                              ·Loose or disconnected starter motor cable.
                                              ·Faulty starter relay switch.


  Check the starter relay coil     Abnormal      ·Faulty side stand switch.
  ground line                                    ·Loose or poor contact of connector.
                                                 ·Open or short circuit in wire harness.
              Normal


       (Go to following page)




20-3