16. BATTERY/CHARGING SYSTEM
RESISTOR INSPECTION
Remove the frame front cover. ( 2-3)
Measure the resistance between the resistor B
pink wire and ground.
Measure the resistance between the resistor A
green/black wire and ground.
Resistances:
Resistor A: 9.910.5
Resistor B: 5.66.2
Faulty resistor is the cause of faulty
operation of the auto bystarter.
Resister A Resister B
REGULATOR/RECTIFIER
INSPECTION
Bolt
Remove the frame body cover. ( 2-3)
Disconnect the regulator/rectifier wire
coupler and remove the bolt to remove the
regulator/rectifier.
Measure the resistances between the
terminals.
Replace the regulator/rectifier if the readings
are not within the specifications in the table
below.
· Due to the semiconductor in circuit, it
is necessary to use a specified tester
for accurate testing. Use of an Coupler Regulator/Rectifier
improper tester in an improper range
may give false readings.
· Use a Sanwa Electric Tester (07208- C (Yellow)
0020000) or Kowa Electric Tester A (Red)
(TH-5H). The proper range for
testing is listed below.
Model Brand Range
SP-10D Sanwa K
TH-5H Kowa 100
Probe
Probe(-) A (R) B (W) C (Y) D (G)
A (R)
B (W) 3-10K B (White) D (Green)
C (Y) 33-35K
D (G) 33-35K
16-6